Send inquiry
items | unit | indicators | Test method |
thickness | (mm) | ≥0.35 | |
area density | (G/M2) | 120 | |
permeability | (G/M2.24h) | 1000-2000 | GB/T 1037-1998 B |
water impermeability | (mm) | 1500-3000 | GB/T 328.10-2007 A |
tensile strengths | (N/50mm) | Parallel 150-230 Lateral 150-220 |
GB/T 328.9-2007 |
Elongation at break | (%) | Parallel ≥35 Lateral ≥35 |
GB/T 328.9-2007 |
tear strength | (N) | ≥ 110 | GB/T 328.9-2007 Bucking Method |
low temperature flexibility | (ºC) | -50 | GB/T 328.15 |
anti-UV | (Month) | 4 | EN133859-1 |
Density range(G/M2) : 80 ~160
Breathable membranes allow insulated structures to easily release excess moisture vapour into the atmosphere and so keep the internal components of wall and roof structures dry, whilst performing the task of a secondary protection membrane and preventing penetration by external environmental impurities such as dirt and rain. These types of membrane are installed on the cold side, or the external side of the insulation beneath the main outer building lining, roof-tiles or cladding.
COMPARED WITH TRADITIONAL WATERPROOFING MATERIALS
Material Project |
PLAYFLY | Modified asphalt(SBS) | PVC waterproof rolls |
WINDPROOF | 5 | 5 | 5 |
VAPOUR PERMEABILITY | 5 | 1 | 1 |
WATERPROOF | 5 | 5 | 5 |
TENSILE FORCE | 4 | 5 | 5 |
ANTI-AGING | 5 | 2 | 4 |
WEIGHT | 1 | 3 | 3 |
WARM-KEEPING PERFORMANCE |
5 (REFLECTION) | 1 | 5 |
DEGREE OF CONSTRUCTION DIFFICULTY |
1 (EASY, MECHANICAL FIXING, NO ADHESIVE) |
5 (COMLICATED, NEED TO HEAT) |
4 (NEED ADHESIVE) |
ENVIRONMENTAL PROTECTION | 5 (100% RECYCLABLE, CLEAN WHILE CONSTRUCTION, NO TOXIC GAS |
1 (LOW RECYCLABLE RATE, RELEASE TOXIC GAS WHEN HEATING) |
2 (LOW RECYCLABLE RATE, RELEASE HARMFUL ODOR WHEN WHILE CONSTRUCTION,) |
Related standards, specification and applications
ITEM | STANDARD | STANDARD NO. | PLANNING AUTHORITY |
APPLICATION OF PLAYFLY |
National standard | Technical specification for slope roof engineering |
GB50693-2011 | Ministy of Housing and Urban-Rural Development of the People's Republic of China |
Roof |
Occupation standard | Technical specification for waterproof protection of building exterior wall |
JGJ/T235-2011-7-12 | China Academy of Building Research |
Exterior wall |
Design specifications of steel structure residence |
CECS261-2009 | China Association for Engineering Construction Standardization |
The exterior wall and roof of steel structure residence |
|
National technical measure |
National technical measure for engineering design of civilian construction--planning, architecture,landscape |
2009JSCS-J | China Building Standard Design & Research Institute |
All |
National Standard Atlas |
Energy-saving structure of public building |
06J908-1/-2 | All | |
Roof and wall building structure 2 of profiled steel sheet and laminboard |
06J925-2 | Metal exterior wall and roof |
||
Roof and wall building structure 3 of profiled steel sheet and laminboard |
08J925-3 | |||
Wooden structure residence |
07SJ924 | Exterior wall and roof |
||
Practice and method of energy-saving project for building envelope structure |
09J908-3 | All | ||
Sloping Roof structure | 09J202-1 | Roof |
Engineering cases